01934 641 446

Close Fitting Ridge

Available in 750mm Girth
To suit roof pitches: 12.5 & 15 Degrees only
Available in 900mm Girth
To suit roof pitches: 5, 7.5, 10, 12.5, 15, 17.5, 20, 22.5 Degrees
Available in 1800mm* Girth
To suit roof pitches: 10, 12.5, 15, 17.5, 22.5 Degrees
* 1800mm Fragile – Further reinforcement is required under the ridge to conform to HSG33

These ridge fittings meet the requirements of HSG-33 Health and Safety Roof Work Manual.

Please note any ridges fitted to the old conventional method DO NOT meet the requirements of HSG-33

Ventilation Ridge

Available in 750mm Girth
To suit roof pitches 12.5 & 15 Degrees only
Available in 900mm Girth
To suit pitches: 5, 7.5, 10, 12.5, 15, 17.5, 20, 22.5 Degrees
Available in 1800mm* Girth
To suit pitches: 10, 12.5, 15, 17.5, 22.5 Degrees
* 1800mm Fragile – Further reinforcement is required under the ridge to conform to HSG33
Vent opening dimension 100mm (height) x 732.5mm (maximum width)

These ridge fittings meet the requirements of HSG-33 Health and Safety Roof Work Manual.

Please note any ridges fitted to the old conventional method DO NOT meet the requirements of HSG-33

Two Piece Adjustable Ridges Close Fitting

These ridge fittings meet the requirements of HSG-33 Health and Safety Roof Work Manual.

Please note any ridges fitted to the old conventional method DO NOT meet the requirements of HSG-33

Two Piece Adjustable Ridges Ventilated

Vent opening dimension 100mm (height) x 732.5mm (maximum width)

These ridge fittings meet the requirements of HSG-33 Health and Safety Roof Work Manual.

Please note any ridges fitted to the old conventional method DO NOT meet the requirements of HSG-33

Two Piece Adjustable Ridges Plain Wing

These ridge fittings meet the requirements of HSG-33 Health and Safety Roof Work Manual.
Please note any ridges fitted to the old conventional method DO NOT meet the requirements of HSG-33.

Finials

Disc

Diamond

Hooded

One piece Disc Finials, Diamond Finials or two piece Hooded Finials are a good option used to close the gable end detail of any EUROSIX two piece ridge fittings.

Open Protected Ridge

Efficient ventilation is important in any livestock building as it supports animal welfare by reducing moisture levels which can carry bacteria and disease.

These ridge fittings meet the requirements of HSG-33 Health and Safety Roof Work Manual.

Please note any ridges fitted to the old conventional method DO NOT meet the requirements of HSG-33

Intermediate purlins positioned along the fixing line can be used with the Open Ridge system to secure the fixing through sheeting.

Cranked Barge Boards

Plain Wing Cranked Barge Board

For use when a one piece ridge is fitted (finials are required when 2 piece ridges are fixed)
Available in 200x200mm wing at 1300mm & 2200mm Girth
Available in 300x300mm wing at 1300mm Girth Only

To Suit Roof Pitches:
5, 7.5, 10, 12.5, 15, 17.5, 22.5 Degrees

Roll Top Cranked Barge Board

For use when a one piece ridge is fitted (finials are required when 2 piece ridges are fixed)
Available in 200x200mm wing at 1300mm & 2200mm Girth

To Suit Roof Pitches:
5, 7.5, 10, 12.5, 15, 17.5, 22.5 Degrees

Vergeline Cranked Barge Board

For use when a one piece ridge is fitted (finials are required when 2 piece ridges are fixed)
Available in 1300mm Girth Only
To Suit Roof Pitches:
10, 12.5, 15, 17.5 22.5 Degrees

Barge Boards

Plain Wing Barge Board

Used to close the verge at gable ends and also vertical cladding
Available in 200x200mm or 300x300mm Wing
Length: 1830mm, 2440mm or 3050mm

Roll Top Barge Board

Used to close the verge at gable ends
Available in 200x200mm Wing
Length: 1830mm, 2440mm or 3050mm
Socket detail provides cover on overlap

Vergeline Barge Board

Used to close the verge at gable ends
Length: 1830mm, 2440mm or 3050mm
Min Lap: 150mm
Socket detail provides cover on overlap
This fitment is handed, please state hand when ordering. This image shows right hand piece.

Apron – Eaves Accessories

Apron Flashing

Used at the junction detail where vertical and standard pitched roofs meet

Net Cover: 1016mm

Eave Filler

Closes corrugation at eaves of single skin cladding

Net Cover: 1016mm

Eave Closure

Closes corrugation at eaves of single skin and insulated cladding system

Net Cover: 1016mm

Movement Joints

Movement Joint

Used to allow a movement / expansion break in larger buildings. Where a movement joint is required, the full EUROSIX sheet beneath it should be cut along the centre of its valley with a space of 25mm to 30mm.

Recommended spacing for Movement Joints are:-

• Buildings with a length of 45 metres or less do not need a Movement Joint.

• Buildings with a length of 45 metres – 75 metres require one run of Movement Joints.

• Another Movement Joint will be required every additional 30 metres.

• Movement Joints require a minimum end lap of 150mm.

• Movement Joints are fixed directly into purlins (not through sheets)

• Fixings should go through the centre point of the Movement Joints at each Purlin position

Cranked Movement Joint

Fixed on the ridge detail to overlap the top end detail of a straight Movement Joint. Fixings specification is the same as straight movement joints.

Movement Joint 2 Piece Ridge

This is a flexible 2 piece movement joint ridge section which adjusts to fit at the crown of a duo-pitch roof.

Movement Joint Stop End

Used to close the open end of a straight Movement Joint
at the eaves.