Profile Data

Standard Overlap Fixing Detail
EUROSIX reinforced roof pitch down to 5º
Manufacturers recommendations for Tek Screws

Sheltered & moderate exposure sites

Minimum Roof Pitch
(as laid)
End Lap
MM
End Lap
Treatments
Side Lap
Treatments
22.5 and over 150 Unsealed Unsealed
17.5 – 22.5 300 Unsealed Unsealed
15 – 17.5 150 Sealed Unsealed
10 – 15 150 Sealed Sealed
5 – 10 300 Double
Sealed
Sealed

Moderate & severe exposure sites

Minimum Roof Pitch
(as laid)
End Lap
MM
End Lap
Treatments
Side Lap
Treatments
22.5 and over 150 Unsealed Unsealed
17.5 – 22.5 150 Sealed Unsealed
15 – 17.5 150 Sealed Sealed
10 – 15 300 Sealed Sealed
5 – 10 300 Double
Sealed
Sealed

End and side overlap treatment

End laps to main sheeting runs are determined according to the roof pitch and site exposure conditions. Lap sizes and corresponding sealing treatment are given in the table above.

Where wind suction forces are likely to exceed 2000N/sq.m or the length of roof slope exceeds 32m, please refer to current building regulations and procedures.